AIMS LIVER BIOPSY ON CHIPLiver Biopsy

→ Increase biopsies viability in long term culture liver biopsy
→ Imaging and biochemical quantification of drug effect
→ Interface blood vessel/hepatocyte
→ DILI assessment based on the biochemical marker and morphometric read-out

FEATURES LIVER Biopsy

→ Temperature: 37°CLIVER BIOPSY ON CHIP
→ Gas: normoxia & hypoxia
→ Perfusion mode: pulse
→ Culture unit: 24 well multi-well & 2 custom microfluidic chip

RESULTS

→ Metabolic functions maintain over 7 days (CYP450, EROD…)
→ First morphometric criteria acquired: necrosis assessment (edges, center)
→ Biochemical markers and DILI assessment ongoingLIVER BIOPSY ON CHIP

PERSPECTIVE

→ Going to super-resolution to image eventual effect of drugs on endothelial nanopores structures (supposed target of toxicity)
→ Going above 7 days to mimic chronic exposure (several plasmatic peaks patterns..)

Liver Biopsy

This project received funding from the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie Grant Agreement No. 766181, project “DeLIVER”.

admin_inno

Recent Posts

Multiorgan Microphysiological Systems as Tools to Interrogate Interorgan Crosstalk and Complex Diseases

Introduction MPS (Multiorgan Microphysiological Systems) have evolved from tools to reduce animal experimentation and improve…

3 years ago

Microfluidic organ-on-chip system for multi-analyte monitoring of metabolites in 3D cell cultures

Introduction The researchers created a microfluidic organ-on-chip solution with integrated electrochemical microsensor arrays enabling compartmentalized…

3 years ago

A new microfluidic method enabling the generation of multi-layered tissues-on-chips using skin cells as a proof of concept

Introduction The state of the art for tissues-on-chips using skin cells had been lacking for…

3 years ago